Manual fire alarm boxes pull stations the height of the manual fire alarm boxes shall be a minimum of 42 inches and a maximum of 54 inches measured vertically from the floor level to the activating handle or lever of the box.

Minimum how feet fire alarm box each floor.

Manual fire alarm boxes shall be located a maximum of feet from the entrance to each exit 5 sprinkler protection is required for exterior balconies decks and ground floor patios of dweeling units where the building is of construction and a roof or deck exists above. Manual fire alarm boxes shall be red in color. In this case height is measured from the floor to the operable part of each manual fire alarm box according to section 5 13 4 of nfpa 72 2007 edition mounting height must be between 3 and 4 feet from floor to handle. As to mounting height of manual fire alarm pull stations nfpa 72 national fire alarm and signal code 2016 ed.

Manual fire alarm boxes shall be located not more than feet from the enterance of each exit. 5 a manual actuation device shall be located at or near a means of egress from the cooking area a minimum of feet and a maximum of feet from the kitchen exhaust system. All of the above. A fire area below grade exceeding 1 500 sq ft.

Nfpa 72 further clarifies that manual fire alarm boxes shall be located within 5 feet 60 inches of the exit doorway opening at each exit on each floor. All subgroup r 1 occupancies unless they meet a series of fire protection measures and exit accessibility requirements detailed in article 907 2 8. To determine the required hourly rating of such fire barriers separating the fire areas one would have to consult table 707 3 10. Section 17 14 5 states the operable part of a manual actuated alarm initiating device shall not be less than 42 1 07 m and not more than 48 1 22 m from the finished floor.

Each floor exit stairs fire pump room fcc. 2007 california fire code section 907 4 2 and nfpa 72 2002 section 5 12 6 2010 california fire code section 907 4 1 and nfpa 72 2010 section 17 14 6. What minimum number of fire alarm control circuits for phase i recall is required for each group of elevators. A fire area located more than three stories above grade.

On the drawing the proper mounting height for a manual fire alarm box is to the top of the device.

Smoke Detector Spacing For High Ceiling Spaces

Smoke Detector Spacing For High Ceiling Spaces

Codes Standards Regulatory Information

Codes Standards Regulatory Information

Nicet Fire Alarm Tech Level 1 Practice Test 9 Ppt Download

Nicet Fire Alarm Tech Level 1 Practice Test 9 Ppt Download

Https Pdc Arizona Edu Dssarchive Rev8 Specificspec 2016720 Pdf

Https Pdc Arizona Edu Dssarchive Rev8 Specificspec 2016720 Pdf

Source : pinterest.com